With SPE Offshore Europe 2019 coming to a close for this year, it has been a very busy week for EPIT. Alongside participation at the show, EPIT co-hosted a successful BBQ with our premises situated only five minutes from the new P&J Live TECA complex.
We would like to thank everyone who took time to attend, and hope you enjoyed your afternoon & burger.
One of the highlights was our Operations Director Martin Constable carrying out a live explosion demonstration.
The demonstration was used to show the audience how Ex ‘d’ (flameproof) equipment works, and is described below.
*Definition of Ex d Equipment*
“An enclosure in which the parts which can ignite an explosive gas atmosphere are placed and which can withstand the pressure developed during an internal explosion of an explosive mixture, and which prevents the transmission of the explosion to the explosive gas atmosphere surrounding the enclosure”.
At the centre of this demonstration is a small Ex d enclosure (approx 80mm x 100mm) in which the spacing or gap between the lid and box can be adjusted by means of a cam to either transmit an internal explosion to an outside explosive atmosphere or contain the explosion. The Ex’d’ enclosure is housed inside another box (approx. 200mm x 300mm) and both are fitted with perspex lids to enable the internal ignition to be witnessed. Spark plugs and igniter units are used to ignite the gas (butane) and air mixture inside and outside the enclosure at the appropriate time. The unit is self contained except for the gas metering facility and power to operate the gas mixing fan, these units are also installed in boxes (approx. 200mm x 300mm).
Two coarse threaded plugs are provided to permit gas to enter the flameproof enclosure and then to be sealed prior to ignition. Following ignition, the plugs are removed and the fan operated to purge the burnt gas.
What is fascinating with this unit is that it allows the delegates to see the flame ignited on the inside of the flameproof enclosure and not transmit to the flammable atmosphere outside because the gap between the cover and enclosure is within the tolerance permitted by the flameproof standard. The gas is then ignited on the outside of the enclosure to demonstrate the validity of the test.
EXCELLENT
Based on 38 reviews
Posted on Googlemichael casson11 March 2026Trustindex verifies that the original source of the review is Google.
Great presentation by the instructors and prep for Compex 01 - 04 examination. Highly recommendedPosted on GoogleViaceslav Gaiducenia12 January 2026Trustindex verifies that the original source of the review is Google.
I did compex 01-04. English is not my first language. I got extra support, a bit of extra explonation, extra advice. All of this was super helpful. The instructors were very knowlagable, passionate and well tempered. I failed one of the units but I passed it second time.Posted on GoogleCameron Bowyer18 November 2025Trustindex verifies that the original source of the review is Google.
I had an excellent experience training with EPIT Aberdeen. The instructors were incredibly knowledgeable, professional, and clearly passionate about what they do. The facilities and equipment are top-quality, and the training was delivered in a way that was both practical and engaging. Everything was explained thoroughly, with real-world examples that made the content easy to understand and apply. The staff were friendly and supportive throughout, creating a really positive learning environment. I left feeling confident, well-prepared, and genuinely impressed with the standard of training. Highly recommend EPIT Aberdeen to anyone looking for high-quality, industry-leading courses.Posted on GoogleShawn Clark12 September 2025Trustindex verifies that the original source of the review is Google.
Done the CompEx Ex01-Ex04 with Mike and Dodd, and they were both excellent! They both broke things down and made them easier to understand, as well as being genuinely good people who you can have a normal conversation and laugh with!Posted on GoogleJohn Soutar11 June 2025Trustindex verifies that the original source of the review is Google.
An absolutely brilliant training and test facility that made the dreaded "Compex Refresher" course, a far more enjoyable and beneficial experience. From the great training material to the very knowledgeable instructors, it all helped to teach us about the new practices and standards in Compex and I certainly left knowing more than I did when I walk through the door Monday morning. Thanks to the all staff! 5*Posted on GoogleQuinn MacDonald30 April 2025Trustindex verifies that the original source of the review is Google.
Excellent facilities and the instructors were brilliant at teaching you the course materials along with real world advice and practicesPosted on GoogleAndrei Lerca4 March 2025Trustindex verifies that the original source of the review is Google.
Great training center powered by passionate people and a very beautiful reception.Posted on Googlejames Lombardo27 November 2024Trustindex verifies that the original source of the review is Google.
Most reliable and Very professionalPosted on GoogleAlistair Strachan (Ally)17 September 2024Trustindex verifies that the original source of the review is Google.
Been here twice, superb facilities and certainly the best out of the 3 different venues I've attended for compex.
Please complete the form below and a member of our admin team will contact you regarding available dates.
Read EPIT Group’s full Terms & Conditions and Privacy Policy.
Gases & Vapours (EX01 – Ex04)
Electrical / Instrument Craftpersons & Engineers Install, Inspect & Maintain: Gas & Vapours
| Header Column #1 | |
|---|---|
| Industries | Principal to all Ex environments, with direct application in hazardous vapour and gas environments. |
| Entry Qualifications Guidance | Level 3, ECS Gold Card, National Diploma or equivalent.
Disipline:
|
| Entry Knowledge - Expected |
|
| Entry Skills - Expected |
|
| Job Roles Aspiring to or operating in |
|
| Entry Experience Guidance |
|
| Entry Knowledge - Desirable |
|
| Entry Skills - Desirable |
|
Gases & Vapours (EX01 – Ex04)
Electrical / Instrument Craftpersons & Engineers Install, Inspect & Maintain: Gas & Vapours
| Header Column #1 | |
|---|---|
| Industries | Principal to all Ex environments, with direct application in hazardous vapour and gas environments. |
| Entry Qualifications Guidance | Level 3, ECS Gold Card, National Diploma or equivalent.
Disipline:
|
| Entry Knowledge - Expected |
|
| Entry Skills - Expected |
|
| Job Roles Aspiring to or operating in |
|
| Entry Experience Guidance |
|
| Entry Knowledge - Desirable |
|
| Entry Skills - Desirable |
|