CE Marking Consultancy for Pipeline Monitoring
Equipment Manufacturer

A UK-based manufacturer of pipeline monitoring instrumentation engaged EPIT Group for specialist CE Marking consultancy to assess and support the certification of a new speed control instrument intended for use in Zone 1 hazardous areas. The client had a specific requirement from their end customer for the equipment to be CE marked prior to deployment.

Challenge

The project involved the development of a speed control instrument that would operate within a Zone 1 hazardous area. The client’s design included several compliance sensitive components, such as rotating parts, battery operated modules, and externally mounted sensors. These sensors required a suitable method of explosion protection, and the overall equipment needed to meet strict conformity requirements.

A key risk was that failure to achieve CE compliance would not only prevent the product from entering the market but also trigger costly design changes and extended timelines. The client required technical expertise to evaluate the equipment against applicable regulations and advise on an achievable certification route.

Solution

EPIT delivered a focused CE Marking consultancy programme to guide the client from concept to certification:

Feasibility Review and Zoning Requirements
EPIT carried out an initial feasibility study to assess whether the proposed equipment could be made suitable for use in a Zone 1 environment. This included reviewing mechanical and electrical design elements in relation to suitable type of explosion protection.

Explosion Protection Evaluation
The consultants advised on the most suitable protection strategy for the system. Intrinsic safety (Ex i) was recommended for the sensor interface, while other components were aligned with relevant protection concepts to meet safety requirements.

Design Support and Standards Application
EPIT provided input throughout the design process to ensure the equipment conformed to harmonised EN standards applicable under CE Marking regulations. This included reviewing design decisions, documentation, and test planning.

Certification Pathway Support
EPIT’s guidance ensured the sample and technical documentation were prepared in line with criteria of the relevant standards. The product was successfully CE marked upon completion of testing.

Results

The client obtained ATEX certification for their speed control instrument, enabling them to CE mark the product and was able to meet the operational and regulatory requirements set by their customer. Following the successful outcome, the client returned to EPIT for further support on a subsequent compliance project.

Client Impact

CE Compliance Achieved: the client met all certification requirements through targeted guidance and a structured compliance route.

Commercial Opportunity Secured: CE Marking enabled the client to deliver the product into a regulated market and fulfil contractual obligations.

Technical Assurance: EPIT’s experience ensured the proposed protection methods and design decisions were fit for purpose and certification ready.

EPIT’s CE Marking consultancy enabled this instrumentation manufacturer to bring a complex, high integrity product to market while meeting safety and regulatory standards essential for use in hazardous environments.

EXCELLENT
Google star 1Google star 2Google star 3Google star 4Google star 5
Based on 38 reviews
Posted on Google
michael casson
11 March 2026
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Great presentation by the instructors and prep for Compex 01 - 04 examination. Highly recommended
Posted on Google
Viaceslav Gaiducenia
12 January 2026
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
I did compex 01-04. English is not my first language. I got extra support, a bit of extra explonation, extra advice. All of this was super helpful. The instructors were very knowlagable, passionate and well tempered. I failed one of the units but I passed it second time.
Posted on Google
Cameron Bowyer
18 November 2025
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
I had an excellent experience training with EPIT Aberdeen. The instructors were incredibly knowledgeable, professional, and clearly passionate about what they do. The facilities and equipment are top-quality, and the training was delivered in a way that was both practical and engaging. Everything was explained thoroughly, with real-world examples that made the content easy to understand and apply. The staff were friendly and supportive throughout, creating a really positive learning environment. I left feeling confident, well-prepared, and genuinely impressed with the standard of training. Highly recommend EPIT Aberdeen to anyone looking for high-quality, industry-leading courses.
Posted on Google
Shawn Clark
12 September 2025
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Done the CompEx Ex01-Ex04 with Mike and Dodd, and they were both excellent! They both broke things down and made them easier to understand, as well as being genuinely good people who you can have a normal conversation and laugh with!
Posted on Google
John Soutar
11 June 2025
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
An absolutely brilliant training and test facility that made the dreaded "Compex Refresher" course, a far more enjoyable and beneficial experience. From the great training material to the very knowledgeable instructors, it all helped to teach us about the new practices and standards in Compex and I certainly left knowing more than I did when I walk through the door Monday morning. Thanks to the all staff! 5*
Posted on Google
Quinn MacDonald
30 April 2025
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Excellent facilities and the instructors were brilliant at teaching you the course materials along with real world advice and practices
Posted on Google
Andrei Lerca
4 March 2025
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Great training center powered by passionate people and a very beautiful reception.
Posted on Google
james Lombardo
27 November 2024
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Most reliable and Very professional
Posted on Google
Alistair Strachan (Ally)
17 September 2024
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Been here twice, superb facilities and certainly the best out of the 3 different venues I've attended for compex.

Booking Form - ECS Health and Safety Assessment

Please complete the form below and a member of our admin team will contact you regarding available dates.

Terms & Conditions
  • You are agreeing to pay all fees and expenses associated with the selected course.
  • Payment is required before commencement of the course.
  • The course fee includes refreshments, lunch and course material.
  • Failure to attend without prior cancellation will result in the loss of the fee.
  • Results will not be issued until payment has been received.
Cancellation Charges
  • 15 working days or less prior to the course start date, 100% cancellation charge will apply.
  • 16-20 working days prior to the course start date, 50% cancellation charge will apply.
  • 21-25 working days prior to the course start date, 25% cancellation charge will apply.

Read EPIT Group’s full Terms & Conditions and Privacy Policy.

CompEx Entry Requirements Guidance

Gases & Vapours (EX01 – Ex04)

Electrical / Instrument Craftpersons & Engineers Install, Inspect & Maintain: Gas & Vapours

Header Column #1
IndustriesPrincipal to all Ex environments, with direct application in hazardous vapour and gas environments.
Entry Qualifications
Guidance
Level 3, ECS Gold Card, National Diploma or equivalent. Disipline:
  • Electrotechnical
  • Instrumentation
Subject to knowledge, skill and experience candidates may benefit from Ex F+
Entry Knowledge - Expected
  • Knows the relevant legislative, regulatory, local requirements
  • Understands procedures for safe working practice and systems of work in an industrial setting
  • Can read and interpret relevant engineering drawings, related specifications, quality standards and equipment manuals
  • Understands the hierarchy of responsibilities in relation to reporting and decision-making
Entry Skills - Expected
  • Practical skills in engineering assembly of a complexity consistent with that of a level 3 craftsperson
  • Can apply safe working practices including safe isolation to meet the requirements of statutory and non-statutory regulations
  • Can safely install, inspect, test, commission, diagnose and correct faults in electrical plant, instrumentation, associated cabling, cabling supports and equipment
  • Can select, gland & terminate industrial type cables to a suitable component and associated cable tray in line with details on the appropriate specification
  • Can interpret manufacturers documentation for correct installation,maintenance and inspection
Job Roles
Aspiring to or operating in
  • Installation or Maintenance Electrician
  • Electrical or Instrument Technician
  • Engineers
Entry Experience
Guidance
  • 2 + years' experience operating in a site / industrial environment
  • Installing, inspecting, testing and/or maintaining equipment in an industrial setting
Entry Knowledge - Desirable
  • Understands the need for and methods of achieving safe working practice in gas and vapour Ex environments
  • Has basic practical, theoretical and technological knowledge and understanding of gas and vapour Ex environments
  • Has a basic understanding of the requirements, materials and equipment considerations, in relation to working in gas and vapour Ex environments
Entry Skills - Desirable
  • Can select and install a variety of Ex certified cables glands and terminate conductors into equipment
  • Can understand the principles of electrical protection concepts including selection, installation and maintenance
  • Understands intrinsically safe concept of protection and installation including the importance of documentation
  • Can inspect new and existing equipment in accordance with appropriate inspection techniques relevant to the different grades of inspection

CompEx Entry Requirements Guidance

Gases & Vapours (EX01 – Ex04)

Electrical / Instrument Craftpersons & Engineers Install, Inspect & Maintain: Gas & Vapours

Header Column #1
IndustriesPrincipal to all Ex environments, with direct application in hazardous vapour and gas environments.
Entry Qualifications
Guidance
Level 3, ECS Gold Card, National Diploma or equivalent. Disipline:
  • Electrotechnical
  • Instrumentation
Subject to knowledge, skill and experience candidates may benefit from Ex F+
Entry Knowledge - Expected
  • Knows the relevant legislative, regulatory, local requirements
  • Understands procedures for safe working practice and systems of work in an industrial setting
  • Can read and interpret relevant engineering drawings, related specifications, quality standards and equipment manuals
  • Understands the hierarchy of responsibilities in relation to reporting and decision-making
Entry Skills - Expected
  • Practical skills in engineering assembly of a complexity consistent with that of a level 3 craftsperson
  • Can apply safe working practices including safe isolation to meet the requirements of statutory and non-statutory regulations
  • Can safely install, inspect, test, commission, diagnose and correct faults in electrical plant, instrumentation, associated cabling, cabling supports and equipment
  • Can select, gland & terminate industrial type cables to a suitable component and associated cable tray in line with details on the appropriate specification
  • Can interpret manufacturers documentation for correct installation,maintenance and inspection
Job Roles
Aspiring to or operating in
  • Installation or Maintenance Electrician
  • Electrical or Instrument Technician
  • Engineers
Entry Experience
Guidance
  • 2 + years' experience operating in a site / industrial environment
  • Installing, inspecting, testing and/or maintaining equipment in an industrial setting
Entry Knowledge - Desirable
  • Understands the need for and methods of achieving safe working practice in gas and vapour Ex environments
  • Has basic practical, theoretical and technological knowledge and understanding of gas and vapour Ex environments
  • Has a basic understanding of the requirements, materials and equipment considerations, in relation to working in gas and vapour Ex environments
Entry Skills - Desirable
  • Can select and install a variety of Ex certified cables glands and terminate conductors into equipment
  • Can understand the principles of electrical protection concepts including selection, installation and maintenance
  • Understands intrinsically safe concept of protection and installation including the importance of documentation
  • Can inspect new and existing equipment in accordance with appropriate inspection techniques relevant to the different grades of inspection